SR750i - SR500i DC UPS / Battery Chargers » Helios Power Solutions Group

SR 500i – SR 750i NO Break DC UPS 500W – 750W

Brand: HELIOS POWER SOLUTIONS

SKU: HPS-PS-DC-UPS-SR500i-SR750i
  • Replaced by SR500HI and SR750HI
  • Deep discharge protection for battery
  • Battery circuit overload , short circuit protection and reverse polarity protection for battery
  • Automatic temperature compensated output
  • Power loss & battery system alarms
  • 24 Month Warranty
No Longer Available

This product is no longer available from Helios Power Solutions. Please contact our our Technical Sales Engineers for suitable alternatives.

Description

SR500i & SR750i Industrial DC UPS

No – Break ™ DC Uninterruptible Power Supply TECHNOLOGY 

Helios Power Solutions proprietary No-Break ™ DC UPS Technology represents a truly unique, comprehensive approach to providing uninterruptible and secure DC power when you need it. The system maximises the integrity of standby battery installations whilst optimising the life and availability of the backup batteries.

The No – Break ™ DC UPS intelligent system provides a vastly improved solution over the traditional methods of float charger plus battery. The battery is accurately charged with independent current limit and you cannot overload the charger or overheat the battery.

The No – Break ™ DC UPS highly efficient system is the ideal solution for:

  • Systems which require no transition from mains to battery backup
  • Applications having standing load with back up standby battery installed
  • Cost-effective management of your battery system investment
  • Mission Critical systems from 100W to 750W and above

Critical factors in the lifetime and capacity of (lead-acid) batteries

  • Temperature compensation
  • Controlled charge current
  • Regular check up
  • Deep discharge protection

Unique additional features of the No – Break ™ DC UPS system

  • Battery Detection: Monitors integrity of battery circuit hourly (battery missing, open fuse/electronic breaker)
  • Battery Condition Test (0ption): Indicative test of battery autonomy at predetermined intervals (automated battery condition check, ideal for remote sites).
  • Configurable Software 
  • Adjustable Load 
  • Communications Interface Port: (Options RS485 , RS232 , Ethernet)
We are offline - Send us an email
Sorry, we are not online at the moment. Please send a message and we'll reply to you. Please include your region so we can connect you with the correct team.
In case we get disconnected, please give us some info so we can follow up with you.
    ×
    File size larger than 50 Mb
    ×
    File type not allowed
    Send chat transcript to your email:
    ×
    Transcript sent!
    Are you sure you want to close this chat?
    Thank you. We would appreciate it if you could rate this chat

    No, thanks