E-one is a compact inverter providing a pure sine wave AC supply. In conjunction with a DC Power system, it provides an excellent AC backup solution. It uses the latest inverter technology, providing superior energy efficiency in a compact size.e-one inverter has DC input on front terminal, AC output socket protected with 10 A fuse.e-one can be easily rack mounted, wall, or desk mounted.
Best in-class solution?
With dimensions of 1U x 342 mm x 221 mm, this very small inverter occupies just 3,300 cm³.
We also guarantee a maximum ripple voltage of 0.01%, or 0.048V on the DC source. In practical terms, this means almost no disturbances reach your DC load or batteries; a great benefit as disturbances considerably reduce battery life.
To minimize your maintenance costs, E-one has incorporated a variable fan speed for cooling. The fan’s speed changes, or it switches off entirely, according to need. This reduces fouling and other maintenance problems.
Finally, regarding reliability, the e-one inverter is based on Y-one inverter which has the lowest conceivable failure rate: 0%.
For which application?
e-one is the ideal solution for powering and securing any AC equipment; maintenance, supervision, cooling, security, access or small cells for 5G. It was designed for base stations (BTS, NodeB and eNodeB) for mobile telecommunication, fixed telecommunication and railway communication (GSMR).
POWER | REG 1000 VA / 800W |
EMC (immunity) | EN 61000-4-2 up to 6 |
EMC (emission) (class) | EN 55022 (A) |
Safety | IEC 60950-1 |
Cooling / Isolation | Forced / Doubled |
MTBF | 200 000 hrs |
Efficiency DC/AC at 54 VDC | 0.9 |
Dielectric strength DC/AC | 4300 Vdc |
RoHS | Compliant |
Vibration | GR63 office vibration 0 to 100 hz-0.1 g / transport vibration 5-100 Hz 0.5 g 100 to 500 hz-1.5 g / Drop test |
Operating conditions | Self adaptive to wide operating conditions and comprehensive table of troubleshooting codes |
Altitude above sea without de-rating | < 1500 m / derating > 1500 m – 0.8 % per 100 m |
Ambient / storage temperature / relative humidity | -20 to 50 ° C / -40 to 70 ° C / 95 %, non-condensing |
Material (casing) | Coated steel |
AC OUTPUT POWER | |
Nominal Output power (VA) / (W) | 1000 VA / 800 W |
Short time overload capacity | 150 % (15 seconds) within T° range |
Admissible load power factor | 0 lagging to 0 leading |
DC INPUT SPECIFICATIONS | |
Nominal voltage (DC) | 48 V |
Voltage range (DC) | 40 – 60 V |
Nominal current at 800 W / 48 VDC | 19 A |
Maximum input current (for 15 second) / voltage ripple | 28 A / 2 mV psopho @ 48 V – 80% LOAD |
AC OUTPUT SPECIFICATIONS | |
Nominal voltage (AC*) | 230 V |
Frequency / frequency accuracy | 50 or 60 Hz / ± 0.01 % |
Total harmonic distortion (resistive load) | < 1.5 % |
Load impact recovery time | 0.4 ms |
Turn on delay | 20 s |
Nominal current. Protected against reverse current | 4.4 A at 230 VAC |
Crest factor at nominal power | 3 : 1 |
With short circuit management and protection | 3 : 1 |
SIGNALING & SUPERVISION | |
Display | Front LED |
Alarms output / supervision | Dry contact on the front |
Remote on / off | On the front |