FXM 650

Industrial Rack Mount AC UPS 650 VA

FXM uninterruptible power supply (UPS ) modules provide clean, reliable power control and management as part of a complete UPS solution. Automatic Voltage Regulation (AVR) provides power stability in unpredictable environments and constant voltage during variable power conditions. Temperature compensated battery charging protects batteries from over charging at extreme temperatures, extending battery life. Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting. Control and power connection panels can be rotated for mounting and display in any orientation** for viewing preference.

Other Smart Features Of the FXM Family Include:

  • Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting
  • A wide operating temperature range of -40 to 74°C (-40 to 165°F)¹ is suitable for extreme operating environments
  • Temperature compensated battery charging protects batteries from over-charging at extreme temperatures, extending the life of the battery

¹ Power module only. Output power derates after 55°C (122°F) for FXM 350, 650 and 1100 and after 50°C (122°F) for FXM 2000 (120Vac), 55°C (230Vac).

Power Solutions For Traffic & Intelligent Transportation Systems

For over 40 years, FXM Series of rugged outdoor uninterruptible power supplies (UPS) and backup power solutions have been designed by outdoor power experts to
meet the stringent requirements of the traffic industry, reliably performing in the most extreme environmental conditions, including frigid temperatures, searing desert heat, snow & salt and other environmentally harsh conditions.

By implementing battery backup/UPS solutions into your traffic networks, there is the potential to:

  • Save lives and eliminate severe accidents due to power outages
  • Sustain power to operating systems and controller electronics until utility power is restored
  • Extend life and lower repair cost up to 70% of all protected traffic electronic equipment
  • Maintain traffic flow and intersection safety
  • Reduce expenses by eliminating ghost service call-outs or expensive after-hour

SPECIFICATIONS TABLE

ELECTRICAL
Operating input voltage range: Battery string voltage: ……. 24Vdc
Nominal voltage: …………… 230Vac
Frequency: …………………… Auto-sensing
Input:
Voltage range: 150 to 328Vac
Current: ……………………… 3.0A
Output Voltage: C urrent: ……………………… 2.8A nominal (no c harge c urrent)
Voltage regulation ………. +/- 10% o ver input voltage r ange
Power at 5 5°C: ……………. 650W/VA
MECHANICAL
Dimensions: 88H x 4 32W x 2 29D (mm)
Weight: 11kg (25lbs)