TDK – Lambda GEN+ Series

Variable – Programmable DC Power Supply: 1.7kW – 5kW

The new, five-year warranty, GENESYS+™ 1U programmable power supply series is available in 1.7kW, 2.7kW, 3.4kW and 5kW 19″ rack models and can deliver power ratings up to 5200W, with the highest power density and lightest weight (< 5kg for the 1.7kW, <7.5kg for the 5kW) available in a 1U rack size. It offers voltages of up to 600V and output current up to 500A with constant voltage, constant current and constant power operation. Control of voltage and current slew rate, arbitrary waveform generation and storage, internal resistance simulation and display brightness control are all standard features.

Multiple remote programming methods are available including LAN, USB, RS232 / RS485 and isolated analogue interfaces built-in as standard. Interface options will include IEEE488, Modbus-TCP, EtherCAT and more.
A unique, easy auto configuring master/slave paralleling system enables scalable power systems up to 20kW to be configured.

Features

  • Leading DC Programmable power density 1.7kW, 2.4kW, 3.4kW & 5kW in 1U rack
  • Light-weight 5kW<7.5 kg
  • Wide Range of popular worldwide AC inputs:

G1.7kW: 1ø (85~265VAC)

G2.7kW / G3.4kW: 1ø (170~265VAC), 3ø (208VAC,400VAC)

G5kW: 3ø (208VAC, 400VAC & 480VAC),Wide- range 3ø 480VAC (342VAC ~ 528VAC)

  • Active three-phase PFC (0.94 typical)
  • Output Voltage up to 600V, Current up to 500A
  • Built-in LAN ( 1.5), USB, RS-232/RS-485 Interface
  • Constant Voltage/Constant Current operation modes
  • Internal Resistance Programming Simulation
  • Scalable Power Systems up to 20kW
  • Protection functions (OVP, UVP, UVL, FOLD (CV/CC), OCL, OTP, AC FAIL)
  • Certified LabWindows™/CVI, LabVIEW™, and IVI Drivers
  • Optional IEEE Interface

Applications

Genesys power supplies have been designed to meet the demands of a wide variety of applications such as:

  • Test & Measurement Systems
  • Component Device Testing
  • Manufacturing and Process Control
  • Semiconductor Processing & Burn-in
  • Aerospace & Satellite Testing
  • Medical Imaging
  • Green Technology

Higher Power System can be configured with up to four 5kW units. Each unit is 1U with space between them(zero stack). OEM Designers have a wide variety of inputs from which to select depending on application and location.

Series Table 1.7kW Models

ModelOutput Voltage (VDC)Output Current (A)Output Power (W)
G10-1700~10V0~1701700
G20-850~20V0~851700
G30-560~30V0~561680
G40-420~40V0~421680
G60-280~60V0~281680
G80-210~80V0~211680
G100-170~100V0~171700
G150-11.20~150V0~11.21680
G300-5.60~300V0~5.61680
G600-2.80~600V0~2.81680

Series Table 2.7kW Models

ModelOutput Voltage (VDC)Output Current (A)Output Power (W)
G10-2650~10V0~2652650
G20-1350~20V0~1352700
G30-900~30V0~902700
G40-680~40V0~682720
G60-450~60V0~452700
G80-340~80V0~342720
G100-270~100V0~272700
G150-180~150V0~182700
G300-90~300V0~92700
G600-4.50~600V0~4.52700

Series Table 3.4kW Models

ModelOutput Voltage (VDC)Output Current (A)Output Power (W)
G10-3400~10V0~3403400
G20-1700~20V0~1703400
G30-1120~30V0~1123360
G40-850~40V0~853400
G60-560~60V0~563360
G80-420~80V0~423360
G100-340~100V0~343400
G150-22.50~150V0~22.53375
G300-11.50~300V0~11.53450
G600-5.60~600V0~5.63360

Series Table 5kW Models

ModelOutput Voltage (VDC)Output Current (A)Output Power (W)
G10-5000~10V0~5005000
G20-2500~20V0~2505000
G30-1700~30V0~1705100
G40-1250~40V0~1255000
G60-850~60V0~855100
G80-650~80V0~655200
G100-500~100V0~505000
G150-340~150V0~345100
G200-250~200V0~255000
G300-170~300V0~175100
G600-8.50~600V0~8.55100

Video