Genesys™ 2U Full-Rack (GEN-2U)

5000W DC Programmable Power Supplies

The Genesys™ 2U Full-Rack (GEN-2U) series of 5000W DC Programmable Power Supplies provides high power density (up to 5200W) with a complete set of user-friendly interfaces within a 2U profile.

This series offers Output voltages from 8V (@ 600A) to 600V (@ 8.5A) in both a Three-phase 208VAC Input (170-265VAC, 47-63Hz) and Three-phase 400VAC Input (342-460VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load).

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant), USB (2.0 compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

All models are CE Marked in accordance with the Low Voltage and EMC Directives, are RoHS compliant, have worldwide Safety Angency approvals (UL/cUL 60950-1 and EN 60950-1 listed) and offer a five (5) year Warranty.

Features and options

  • Constant Voltage / Constant Current with automatic crossover
  • Active Power Factor correction
  • Single Phase or Three Phase options
  • Embedded Microprocessor Controller
  • Built in RS232/485 Interface
  • Voltage&Current high resolution adjustment by digital encoders
  • Software calibration
  • Last Setting Memory
  • Independent Remote ON/OFF
  • Parallel Operation (Master/Slave) with active current sharing
  • Remote sensing to compensate for voltage drop of power leads

SERIES TABLE

ModelOutput Voltage (VDC)Output Current ( A )Output Power ( W )
GEN 8-6000~8V0~6004800
GEN 10-5000~10V0~5005000
GEN 16-3100~16V0~3104960
GEN 20-2500~20V0~2505000
GEN 30-1700~30V0~1705100
GEN 40-1250~40V0~1255000
GEN 60-850~60V0~855100
GEN 80-650~80V0~655200
GEN 100-500~100V0~505000
GEN 150-340~150V0~345100
GEN 200-250~200V0~255000
GEN 300-170~300V0~175100
GEN 400-130~400V0~135200
GEN 500-100~500V0~105000
GEN 600-8.50~600V0~8.55100

SPECIFICATIONS TABLE

Input Voltage / Frequency (range)3-Phase, 208V models: 170~265Vac,  47~63Hz , 3-Phase, 400V models: 342~460Vac, 47~63Hz
Inrush Current3-Phase 208V models: Less than 50A, 3-Phase 400V models: Less than 20A
Power Factor3-Phase models: 0.94@208/380Vac, rated output  power.
Parallel OperationUp to 4 identical units in master/slave mode
Operating temp0~50°C, 100% load.
Storage temp-20~85°C
Operating humidity20~90% RH (non-condensing).
Storage humidity10~95% RH (non-condensing).
VibrationMIL-810F, method 514.5, The EUT is fixed to the vibrating surface.
ShockLess than 20G, half sine, 11mSec. Unit is unpacked.
AltitudeOperating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
RoHS ComplianceComplies with the requirements of RoHS directive.