CCL400 – AC/DC Convection Cooled Power Supply 400W

Brand: XP POWER

SKU: HPS-PS-CCL400
This product is available globally.
  • 94% Efficiency
  • 85 VAC to 264 VAC Input
  • 5V Standby
  • 12V 24V 20V 48V output voltage options
  • IT & Medical Safety Approvals

Product Range

SKU Power AC/DC Input Voltage AC/DC Output Voltage 1 AC/DC
CCL400PS24400W88 - 264VAC24V

Description

CCL400 Series

Convection-Cooled DC Power Supply  400W

The universal AC input CCL400 provides 400W of convection cooled output power over the temperature range -40°C to +50°C with derating to +70°C. The temperature range can be extended by the use of conduction cooling to the full 400W at +70°C. Approved for IT and Medical and with a feature set including a 5V standby output, <0.5W standby power, power fail and inhibit

signals the CCL400 is ideal for a wide range of applications where fan cooling is not desirable.

Main Features

  • 400 W Convection-cooled
  • Conduction Cooling For Higher Ambient Operation
  • 94% Efficiency
  • 85 VAC to 264 VAC Input
  • 5V Standby
  • <1W Standby Power
  • IT & Medical Safety Approvals
  • 12V 24V 20V 48V output voltage options
  • Power Fail & Inhibit Signals

Additional information

WeightN/A

SERIES TABLE

Model InputOutputPower
CCL400PS1280 to 264 Vac12 V / 33.3 A400W
CCL400PS2480 to 264 Vac24 V / 16.6 A400W
CCL400PS3080 to 264 Vac30 V / 13.3 A400W
CCL400PS4880 to 264 Vac48 V / 8.3 A400W

SPECIFICATIONS TABLE

Dimensions:CCL: 7.12 x 3.95 x 1.57 in (180.9 x 100.3 x 39.9 mm)
Input Voltage:80-264 VAC (see datasheet)
No Load Input Power:1 W max
Harmonic Currents:EN61000-3-2, class A
Efficiency:93-94%
Operating Temp:-40 °C to +70 °C. Refer to derating curves
Isolation:4000 VAC Input to Output, 2 x MOPP
1500 VAC Input to Ground 1 x MOPP
500 VAC Output to Ground
Worldwide Safety Approvals:IEC60950-1 Ed 2, IEC60601-1 Ed 3.1 Including Risk Management
European Safety Approvals:EN60950-1, EN60601-1, CE Mark
US Safety Approvals:UL60950-1, CSA C22.2 No. 60601-1:08, ANSI/AAMI ES60601-1
EMC:EN55022, Level B conducted and Level A radiated (Level B see datasheet)

View Datasheet