The ECS65 Series has been designed to minimise the load power consuption (<0.5W) and maximise efficiency in order to facilitate equipment design to the latest enviromental legislation.

 

SERIES TABLE

Model  Input Output Power
ECS65US12 80 to 264 Vac 12 V / 5.4 A 65W
ECS65US15 80 to 264 Vac 15 V / 4.3 A 65W
ECS65US18 80 to 264 Vac 18 V / 3.4 A 65W
ECS65US24 80 to 264 Vac 24 V / 2.7 A 65W
ECS65US28 80 to 264 Vac 28 V / 2.3 A 65W
ECS65US48 80 to 264 Vac 48 V / 1.4 A 65W
ECS100US12 80 to 264 Vac 12 V / 8.3 A 100W
ECS100US15 80 to 264 Vac 15 V / 6.7 A 100W
ECS100US18 80 to 264 Vac 18 V / 5.5 A 100W
ECS100US24 80 to 264 Vac 24 V / 4.2 A 100W
ECS100US28 80 to 264 Vac 28 V / 3.6 A 100W
ECS100US48 80 to 264 Vac 48 V / 2.1 A 100W
ECS130US12 80 to 264 Vac 12 V / 10.9 A 130W
ECS130US15 80 to 264 Vac 15 V / 8.7 A 130W
ECS130US18 80 to 264 Vac 18 V / 7.3 A 130W
ECS130US24 80 to 264 Vac 24 V / 5.4 A 130W
ECS130US28 80 to 264 Vac 28 V / 4.7 A 130W
ECS130US48 80 to 264 Vac 48 V / 2.7 A 130W

SPECIFICATIONS TABLE

Dimensions: ECS65: 4.00 x 2.00 x 1.05 in (101.6 x 50.8 x 26.7 mm)
ECS100: 4.00 x 2.00 x 1.25 in (101.6 x 50.8 x 31.8 mm)
ECS130: 4.00 x 2.00 x 1.28 in (101.6 x 50.8 x 32.5 mm)
Input Voltage: 80-264 VAC (275 VAC ECS65) (120-370 VDC), derate output power <90 VAC, see datasheet
No Load Input Power <0.5 W
Harmonic Currents: EN61000-3-2, class A
Efficiency: Up to 90% typical
Operating Temp:  -20 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C
Isolation: 4000 VAC Input to Output 2 x MOPP
1500 VAC Input to Ground 1 x MOPP
500 VDC Output to Ground 1 x MOPP
Worldwide Safety Approvals: IEC60950-1, IEC60601-1
European Safety Approvals: EN60950-1, EN60601-1, including risk management
US Safety Approvals: UL60950-1, CSA22.2 No. 234 per cUL
EMC: EN55011/22 level B conducted
EN55011/22 level A radiated, level B Suffix ‘-B’ models