ICT180S-12BRC Smart Single Bus GMT Broadband DC Load Distribution Panels

Brand: ICT Power

SKU: ICT180S-12BRC
Note: This product is not available in the following regions: Australia
  • 180A peak, 150A continuous system rating 12 GMT fused outputs (15A max. each)
  • Operating voltage range 10-60 volts DC
  • Ethernet-based monitoring and alarm reporting of each output
  • Remote Power Control for remote shutdown or power-cycling of individual outputs
  • HTTPS, TLS1.0, SNMPv1/v2c/v3

Description

ICT180S-12BRC

Smart Single Bus GMT Broadband 48VDC Load Distribution Panels

ICT Intelligent broadband DC load distribution panels feature a built-in Ethernet controller and web server, allowing users to remotely monitor and control loads connected to the panel. Remote Power Control allows individual DC outputs to be managed remotely using the Ethernet connection. This allows connected devices to be turned on and off or power-cycled, potentially averting the need for an on-site service visit.

Power-Cycled DC Loads

System voltage and current, and individual output current readings can be monitored. This can provide an indication of a problem with the system power, or with individual connected loads such as radios, switches, or access points. Text or email alerts can be sent when an alarm is triggered.

Pings Designated I.P. Addresses

The Network Watchdog feature pings a designated I.P. address and will restart an assigned output automatically, allowing devices such as routers to be power-cycled to avoid losing communications to the site. Load shedding is provided with user definable settings for each output, allowing non-essential loads to be automatically shut down in order to reserve battery power for priority loads.

The easy to use ICT Graphical User Interface can be accessed from a secure web browser, or SNMP is provided for users with Network Management Systems.

Applications

  • Broadband communications networks
  • Microwave backhaul
  • DAS
  • Security and surveillance
  • SCADA/PLC power and control
  • Industrial DC power

Other Features

  • Form C contacts
  • Up to 30 days of data logging
  • Restore to previously saved settings after a power loss
  • Independently adjustable load shed settings
  • 5 digital alarm contact inputs for site monitoring and reporting of alarms such as door, water, and smoke detectors

Recommended 1U Rack Mount DC Power Supplies for ICT180S-12BRC DC Distribution Panel

Pro Series 1U Rack Mount DC Power Supply 12V 24V 48V

Compare

PRO 1U Rack Mount Battery Charger/DC UPS: 690W – 1200W

Platinum Series 1U Rack DC Power Supply 12V 24V 48V

Compare

Platinum Series AC/DC Power Supplies with TCP/IP Ethernet: 800W – 1600W

SPECIFICATIONS TABLE

Power Specifications
Nominal Application Voltage48VDC
Operating Voltage Range10 to 60VDC
Panel Current Rating (Peak)180A
Panel Current Rating (Continuous)150A
Number of GMT Fused Outputs12
GMT Fuse Rating (Max)15A(1)(2)

(1) Please follow all recommendations of the fuse manufacturer. Fuses and wiring should be continuously operated at no more than 80% of their current rating.
(2) GMT fuses not included.

Mechanical
Form Factor1RU – 19 Inch rack mount with handles
Dimensions (L x W x H)9.29 x 19.0 x 1.72 in. / 236 x 483 x 44 mm
Weight (lbs/kg)7.0 lbs / 3.2 kg
Fuse PositionFront panel
LED Alarm IndicatorsFront panel
LCD Digital DisplayFront panel
Power ConnectorsDC input stud connectors, DC output terminal blocks, Form C alarm contacts, grounding stud, RJ-45 Ethernet
Site MonitoringFive external dry alarm contacts. Monitors external contact closure, configurable for NO or NC logic, applied voltage 3.3V, 0.4mA for contact closure detection
Operating Temperature Range-30C to +60C
CoolingConvection (fanless)

SERIES TABLE

ICT180S-12BRC12 output Intelligent GMT fuse panel for negative voltage applications (eg. -48 or -24 VDC)
ICT180S-12BRCP12 output Intelligent GMT fuse panel for positive voltage applications (eg. +24 or +48 VDC)
ICT-RA231923 to 19 inch rack reducer kit allows all ICT Distribution Series models to be installed in a 23 inch rack

COOMUNICATIONS & CONTROL

Communications & Control
EthernetTCP/IP built-in web server and graphical user interface, 10/100BASE-T, IEEE 802.3 compatible
Supported ProtocolsIPv4, HTTP, HTTPS, SMTP, DNS, TCP, UDP, ICMP, DHCP, ARP, SNMP v1/v2c/v3
SNMP PortsUDP Port 161, SNMP Traps: UDP Port 162
Firmware UpgradesUpgradeable over Ethernet
SecurityPassword protected, HTTPS, TLS1.0
12 Channel Output MonitoringCurrent draw measured and reported for each output, definable under and over current alarms
Email and SMS AlertsMultiple email or text accounts, adjustable intervals
Data LoggingUp to 30 days at 1 minute sampling rate, csv file download, major event logging
Network WatchdogAutonomously ping up to two I.P. addresses and power-cycle output if no response, definable settings
Remote AlarmsForm C alarm contacts (C/NO/NC)
Remote Power ControlEach DC output on/off selectable
Auto Restore ModeWill return to previous output settings after a power loss
Power-up Delay SequencingUser selectable 0 to 60 second delay between outputs energizing
Auto Load SheddingEach output user definable, manual or auto restart